Compensating Cables
Cables with a PTFE/PFA/ECTFE/FEP insulation are suited for dry, moist and wet rooms and high mechanical strain at high ambient temperatures. PTFE/PFA/ECTFE/FEP insulated cables can be laid outdoors without any problems. They can be laid firmly or flexibly. In the case of flexible laying tensile stress must be avoided. PTFE/PFA/ECTFE/FEP insulated cables have the following properties:
high insulation resistance > 2 TOhm x cm
high abrasion resistance
extremely low dielectric losses
water absorption < 0.01 %
resistant to all ambient conditions
resistant to acids and bases, solvents, fuels, mineral oils, synthetic liquids etc.
high elasticity and tensile strength
resistant to soldering temperatures
Cables without screening resp. with electroplated screening foil and additional wire are available upon request.
Description | TC - Type | Item Number |
TT-465-2KC-0,5L | NiCr-Ni | 2-2300-00063 |
TT-465-2NC-0,25L | NiCrSi-NiSi | 2-2314-00003 |
TT-465-2SC-0,25L | Pt10%Rh-Pt | 2-2305-00016 |
TT-460-2KC-0,25L | NiCr-Ni | 2-2300-00048 |
FEP insulation (fluorethylene-propylene) | |
Temperature range: | laid firmly -100 ... +205°C
|
PFA (polyfluorethylene-acetate) and PTFE (polytetra-fluorethylene) insulation | |
Temperature range: | laid firmly -190...+260°C
|
Burning properties: | flame-inhibiting and self-extinguishing |
It is recommended to obey the following minimum bending radius: | |
Flexible laying: | 10 x outside diameter |
Firm laying: | 4 x outside diameter |
INQUIRE ABOUT THIS PRODUCT